ISO/IEC 17025 facilitates international cooperation by establishing wider acceptance of laboratory test results between countries and organizations. This not only provides global confidence in the work of an organization but also promotes national and international trade through the acceptance of test and calibration data between countries, without the need for additional testing.
ISO 17025 is a quality management system and the main standard for testing and calibration laboratories. ISO 17025 shares many commonalities with ISO 9000 but ISO 17025 evaluates the technical competence in lab testing and calibration services and it applies to organizations that produce testing and calibration results.
To achieve ISO 17025 accreditation, the laboratory's quality management system and technical competence is evaluated thoroughly by a third-party. Audits are conducted on a regular basis to maintain accreditation. ISO 17025 accreditation can only be granted by an authorized accreditation body. Accreditation means that the laboratory has met the Management Requirements and Technical Requirements of ISO17025 and is deemed technically competent to produce calibration and testing results.
ISO 17025 Accreditation proves a laboratory has an acceptable quality management system in place, and it has the ability and competence to provide testing and calibration results. Accredited labs perform tests against the international standards (ISO 17025) and results are mutually acceptable between different governmental and regulatory organizations. The arrangement between accreditation bodies is that accredited members' test results will meet the same minimum quality standard regardless of the accreditation body and that the calibration results would be recognized as if they had performed the calibration themselves.
Acousto-Scan has been assessed by NATA to Comply with ISO17025:2017 and what it can test in it scope of Accreditation.
This allows Acousto-Scan to test international and has been accredited to ILAC.
ILAC is the international organization for accreditation bodies operating in accordance with ISO/IEC 17011 and involved in the accreditation of conformity assessment bodies including calibration laboratories (using ISO/IEC 17025), testing laboratories (using ISO/IEC 17025),
ILAC promotes the increased use and acceptance of accredited calibration, testing, medical testing and inspection data and results, proficiency testing programs and reference materials internationally. Industry, governments, regulators and consumers are encouraged to use and accept results from accredited conformity assessment bodies, including in other economies. By accepting products across national borders, the need for them to undergo additional testing or inspection in each country into which they are provided is removed.
14383
14376
13 Nov 2000
Mr Grant Humphreys
P: +61 0415423334
admin@acoustoscan.com.au
Services available to external clients
SERVICE | PRODUCT | DETERMINANT | TECHNIQUE | PROCEDURE | LIMITATIONS |
---|---|---|---|---|---|
Evaluation of geotechnical and civil construction material - Aggregate properties |
Aggregates |
Particle size distribution |
Sieve analysis |
EN 933-1 FIFA test method 20 |
|
Shape |
Not applicable |
EN 14955 |
|||
Bulk density |
Not applicable |
EN 1097-3 |
|||
Evaluation of mechanical performance of pedestrian and impact attenuation surfaces |
Artificial sports surfaces |
Tensile strength |
Not applicable |
BS EN 12230 |
|
Water infiltration |
Not applicable |
FIFA test method 24 |
Including tests in the field |
||
Pile length above substrate |
Not applicable |
ISO 2549 |
|||
Shock absorption |
Not applicable |
FIFA Test Method 04a |
laboratory and field |
||
Rotational resistance |
Not applicable |
EN 15301, FIFA Test Method 06 |
laboratory and field |
||
Energy of restitution |
Not applicable |
FIFA Test method 11, IRB (International Rugby Board) section 7 |
laboratory and field |
||
Mass per unit area; Pile weight above substrate |
Not applicable |
ISO 8543 |
|||
Joint strength |
Not applicable |
EN 12228 |
|||
Ball roll |
Not applicable |
EN 12234, FIFA Test Method 03 |
laboratory and field |
||
Vertical ball rebound |
Not applicable |
EN 12235, FIFA Test Method 01 |
laboratory and field |
||
Standard vertical deformation |
Not applicable |
FIFA Test Method 05a |
laboratory and field |
||
Thickness of synthetic surface |
Not applicable |
EN 1969 |
|||
Surface regularity |
Not applicable |
EN 13036-7, FIFA Test Method 12 |
laboratory and field |
||
Free pile height |
Not applicable |
FIFA test method 18 |
Including tests in the field |
||
Tuft withdrawal force |
Not applicable |
ISO 4919 |
|||
Tufts per unit area |
Not applicable |
ISO 1763 |
Including tests in the field |
||
Playground surfaces |
Critical fall height |
Transient vibration |
AS 4422 |
laboratory and field |
SERVICE | PRODUCT | DETERMINANT | TECHNIQUE | PROCEDURE | LIMITATIONS |
---|---|---|---|---|---|
Material performance evaluation of elastomers, plastics and composite products |
Prepared test specimens |
Temperature and enthalpy of melting and fusion |
Differential scanning calorimetry (DSC) |
FIFA test method 22 ISO 11357-3 |
Thermogravimetric analysis |
Synthetic infill for sporting turf |
Organic/inorganic ratio |
Thermogravimetric analyser |
FIFA Method 11 |
Thermogravimetric analysis |
|
Material performance evaluation of leather, textiles and related products |
Yarn and sewing thread |
Linear density |
Not applicable |
FIFA test method 23 |
|
Thickness |
Not applicable |
FIFA test method 25 |